Call 08048966909 64% Response Rate

Send Email

Fixed Multi-Point Gas Detectors

There is a wide range of customer needs for gas detection systems to support workplace security management at plants and factories, and these depend on facility scale and on the targeted gases. We provides optimal systems for a broad range of needs, from stand-alone Units for a single type of gas to large-scale systems integrating several hundred gas detectors.
Wall Mount Type Gas Detector Model UV-810
  • Wall Mount Type Gas Detector Model UV-810
  • Wall Mount Type Gas Detector Model UV-810
  • Wall Mount Type Gas Detector Model UV-810
  • Wall Mount Type Gas Detector Model UV-810
  • Wall Mount Type Gas Detector Model UV-810
  • Wall Mount Type Gas Detector Model UV-810
  • Wall Mount Type Gas Detector Model UV-810
  • Wall Mount Type Gas Detector Model UV-810

Wall Mount Type Gas Detector Model UV-810

Get Latest Price

Product Brochure

Product Details:
Minimum Order Quantity1 Number
Display TypeBar graph, Analog
BrandNew Cosmos Electric Co.,Ltd Japan
Model(UV-810)
Power SourceBattery,24 volt DC or 240V AC
Battery Typeas per specifaction
PowerElectric
UsageGas alarm,gas detector
Detecting GasH2s,carbon monoxide, LPG, CH4, H2, O2, NH3 , Toxic Gas, flammable gas,hydrocarbon gas
Wall Mount Type Gas Detector (UV-810)

Features
  • Compact design
  • Standard cases for 3/6/9/12/15 points are available
  • Wide variety of input power sources
  • Can be equipped with a Zener barrier
  • Combination of the V3 series (or V/V2 series) units allows detection of and alarm for various gases
  • Backup power supply unit is available with UVB-810
Specifications
Model UV-810
Points of Indicator Up to 15 point
(line up: 3/6/9/12/15 point type)
Alarm Accuracy As per gas detector:
– Combustible gas: within 25% of alarm value under an identical condition
– Toxic gas: within 30% of alarm value under an identical condition
Alarm Indication
Alarm Sound
Indicator unit
– Alarm lamp: blnks on alarm, lights up by reset, latching (or non-latching)
Alarm unit
– Trouble lamp:
red lamp lights up (1st stage, 2nd stage) when at least one indicator unit is activated
yellow lamp lights up when at least one indicator unit cause a malfunction
External Output Terminal for collective alarm
– 2nd alarm contact: 1a non-voltage (STD) (100 VAC, 1A. 24 VDC, 1A load resistance)
– 1st alarm contact: 1a non-voltage (STD) (100 VAC, 1A. 24 VDC, 1A load resistance)
– Buzzer contact: 1a non-voltage (STD) (100 VAC, 1A. 24 VDC, 1A load resistance)
– Trouble contact: 1a non-voltage (STD) (100 VAC, 1A. 24 VDC, 1A load resistance)
*Collective alarm contacts of 1st alarm and 2nd alarm can be changed to 1b contact (need to specify)
Terminal for individual alarm
– 2nd alarm contact: 1a non-voltage (STD) (250 VAC, 2A. 24 VDC, 2A load resistance)
– 1st alarm contact: 1a non-voltage (STD) (250 VAC, 2A. 24 VDC, 2A load resistance)
Analog output
– Gas concentration analog output signal: 4-20 mA, selectable from 1-5 V (need to specify)
Power Source AC specification: 100-240 VAC ±10%
DC specification: 24 VDC ±10% (need to specify)
Power Consumption AC input: 100-240 V, Pump power supply: 24 VDC
– Power consumption (VA) = (V3 x points of indicator + VAS) x 1.25 (SW power loss)
DC input (24 V ±10%), Pump power supply: 24 VDC
– Power consumption (W) = (V3 x points of indicator + VAS)
**V3 includes power consumption of gas detector
Operating Temperature/
Humidity
-10 to +40 °C (excluding rapid temperature change)
10 to 90 %RH (excluding rapid temperature change, non-condensing)
Built-in Indicator/Alarm Units

Additional Information:

  • Item Code: UV-810
  • Delivery Time: 10 week
Get Best QuoteRequest A Callback

EXPLORE MORE CATEGORIES

Contact Us
 
Thank youYour Enquiry has been sent successfully.