Product Details:
Minimum Order Quantity | 1 Number |
Brand | New Cosmos Electric Japan |
Gas Type | Hydrogen gas detector |
Measurement Range | 0-100% LEL |
Sensor Type | Suction Type |
Voltage | 24 volt |
Usage/Application | Gas Detection |
Additional Information:
Product Details:
Display Type | Digital |
Brand | New cosmos Electric Co., Ltd Japan |
Model Name/Number | KS-7O |
Measurement Range | 0-25 Vol % |
Warranty | 02 year |
Weight | 300 gm approx |
Applications:
Additional Information:
Product Details:
Type | Fixed type |
Model | V-819 |
Number of Model channel | 12 channel models. |
Analogue current | (4 - 20mA) |
Power | Electric |
Application | Industrial |
The V-819 is a fixed odor monitoring system suited for hydrogen sulfide or various aromatic odors monitoring. Application examples include monitoring of factory exhaust and various land borders, in odor monitoring equipment, performance monitoring of indoor air purifier and deodorizing equipment.
The V-819 is based on the V Series fixed detector system, which is a full-featured, modular and multi-gas detection system. The panel is comprised of modular Indicator and Alarm units that can be individually replaced if required. The panel itself comes in the wall mounted, panel mounted or floor-standing design depending on the number of detection channels required. The wall / panel mounted designs come in 3 / 6 / 9 / 12 channel models.Gas monitor |
Four gas monitors |
Gas Monitoring System for Paint Shops |
Gas monitoring system |
Gas monitor |
Odor monitor |
Personal gas monitor |
Additional Information:
Product Details:
Brand | New Cosmos Electric Co., Ltd Japan |
Weight | 63 gm |
Display Type | Digital |
Power Source | Battery |
Can review | Upto 30 alarms |
Degree of protection | IP54 |
Pocket Size | 40 x 86 x 20mm |
Product Details:
Minimum Order Quantity | 1 Unit |
Model Name/Number | KD-5B-N |
Gas Type | LPG,PNG,Methane,Hydrogen,Ammonia |
Operating Temperature | -20 to 60 deg |
Display Type | Analog |
Weight | 1 kg approx |
Sensor Type | Catalytic combustion |
Additional Information:
Product Details:
Detector Type | Fixed Single Gas |
Brand | New cosmos Electric |
Model | NV-120 series |
Model | NV-120Sx |
Detection Principle | Galvanic cell |
Target Gas | Oxygen |
Power Voltage | AC type: 100 to 240 VAC±10% or DC type: 24 VDC (18 to 26.4 VDC) *1 |
Power Consumption*2 | AC type Non-backup power type: Standard 2.0 VA (Max. 3.4 VA) Backup power type: Standard 2.1 VA (Max. 4.7 VA) DC type Non-backup power type: Standard 2.0 W (Max. 3.4 W) |
External Outputs | ???Power output: 24 VDC ± 10% Max.0.3 A ???Signal output: 4-20 mA analog or 1-5 V *1 In the event of failure: ≤ 0.6 mA (for 4-20 mA type) and ≤ 0.25 V (for 1-5 V type) ???1st stage gas alarm contact: Dry, N.O. or N.C.*1 Max. load: 250 VAC 2 A, 30 VDC 2 A (resistive load) ???2nd stage gas alarm contact : Dry, N.O. or N.C.*1 Max. load: 250 VAC 2 A, 30 VDC 2 A (resistive load) ???Fault contact: Dry, N.O. or N.C.*1 Max. load: 250 VAC 2 A, 30 VDC 2 A (resistive load) ???Audio alarm contact: Dry, N.O. Max. load: 250 VAC 2 A, 30 VDC 2 A (resistive load) |
Display | Color LCD with backlight |
Status Indicator | Green POWER LED, red ALARM LED (1st stage gas alarm: flashes and 2nd stage gas alarm: flashes rapidly) and amber FAULT LED |
Gas Alarm | ???1st stage gas alarm: ALARM LED flashes red + LCD turns orange + beeping + voice message “Gas alarm” ???2nd stage gas alarm: ALARM LED rapidly flashes red + LCD turns red + fast beeping + voice message “Gas alarm” |
Fault Alarm Indication | FAULT LED lit amber + error code on display + fast beeping + voice message*3 |
Compliance | RoHS directive (2011/65/EU) *4 |
Color | Case and cover: DIC546 1/2 Backup battery unit: Munsell 10Y8.5/1 |
Mass | Non-backup power type: Approx. 750 g Backup power type: Approx. 2.2 kg |
Dimensions | Non-backup power type: W113 mm×D77 mm×H219 mm Backup power type: W113 mm×D115 mm×H234 mm |
Operating Temperature | Non-backup power type: –10 to 50°C Backup power type: 0 to 40°C No rapid temperature change. |
Operating Humidity | 0 to 90%RH No condensation. |
Backup Power Type*5 | Without intermittent gas-monitoring mode: In the event of a power outage, the unit will continue continuous gas-monitoring for another 120 minutes or more. |
*1. Must be specified at the time of ordering.
*2. Consumption power of the connected gas detector is excluded.
*3. Voice message changes depending on the nature of the fault.
*4. None of the hazardous substances restricted by the RoHS directive is used in this product.
*5. Backup power type units are all AC type units.
*Only New Cosmos-manufactured gas detector can be connected to this product.
*Specifications above may be subject to change without notice.
*N.O.: Normally open. *N.C.: Normally closed.
Connectable Detectors